Determinatio oxygenii permeabilitatis notarum materiarum et continens.
Apta: pellicula, linteum, continens et constructio materiae materia plastica, textilis, corio et metallo.
Modus Coulemeter Sensor
oxygeni vel siccum cum quadam humiditate speciminis ab una parte profluit, et nitrogenium purissimum (gasi baiulum) ad ratem fixum ex altera parte fluit;Differentia oxygenii concentratio inter duo latera speciminis impellit oxygenium ad penetrandum a parte oxygenii speciminis ad latus nitrogenium;Dolor perfusus ad sensorem coulometri per nitrogenium (portitorem gas);Sensor mensurae oxygenii contentum ferebat gasi et oxygeni permeabilitatem speciminis computat.
YBB 00082003、GB/T 19789、ASTM D3985、ASTM F2622、ASTM F1307、ASTM F1927、ISO 15105-2、JIS K7126-B
Original importatum oxygeni sensorem, ppb accurate.
Humiditas temperantiae capacitatis: 35%~ 95% RH, 100% RH, plene automatic, nebulosus.
Temperature imperium pluma: semiconductor frigidus et calidus bidirectionalis imperium, summa praecisio, stabilis et certa.
Fortis environmental aptabilitas: Indoor environment, temperatus X - XXX , quaelibet humiditas, humilis sumptus usus.
specimen lateris lacus probationis signandi institutionem amplificandi.
Intellectus et latae sententiae: potestas in auto-test ad vitandum test sub culpa civitatis;unum clavem initium, plene latis test supplicium.
Software: graphice, totum processum ac elementum magna vigilantia;multiplex fama formats.
Libitum: moduli programmatum GMP computerizationis ratio.
Nomen | Parameter | Nomen | Parameter | |
Umor dolor | 0% RH,35%~95%RH,100%RH | Error Umor | ±1%RH | |
Temperatus dolor | 15℃~50℃ | Temperatus Error | ±0.1℃ | |
Specimen Crassitudo | <3 mm | Gas pressura | ≥0.2 MPa | |
Portitorem gas | 99,999% puritas nitrogenii | Gas influunt carrier | 0~100 cm3/min | |
Interface magnitudine | I / VIII-inch pipe mentis | Magnitudo (L×B×H) mm | 720(L)415(W) ×400(H) | |
Potestas Supple | AC 220V 50Hz | Potentia consummatio | 1200W | |
Exemplar speciale | Model | |||
| YY310--11-A | YY310---31-M | YY310---41-E | |
Specimen Comitis | 1 | 3 | 4 | |
Test Area(cm2) | 50 | 7 | 50 | |
Mensura film Range (cm3/m2.24h) | 0.01~14,000 | 0.05~70,000 | 0.01~14,000 | |
Error film mensura (cm3/m2.24h) | 0.01 | 0.05 | 0.01 | |
Sarcina mensura dolor (cm3/pkg.24h) | 0.0005~70 | / | 0.0005~70 | |
Sarcina mensura erroris (cm3/m2.24h) | 0.0005 | / | 0.0005 | |
Net Pondus (kg) | 52 | 73 | 82 |