Welcome to our websites!

Products

  • YY871B Capillary Effectus Tester

    YY871B Capillary Effectus Tester

    Instrumentum usus:

    Usus est ad determinationem aquae effusio xylinum, textilia, contexenda, cortinas, serica, sudaria, graphea aliaque materia.

     Vexillum occurrite:

    FZ/T01071 et alia signa

  • YY871A Capillary Effect Tester

    YY871A Capillary Effect Tester

    Usus est ad determinationem aquae effusio textilia bombicis, contexuit textilia, plagulas, serica, sudaria, grapha et alia materia.

  • YY(B)871C-Capillaris effectus testor

    YY(B)871C-Capillaris effectus testor

    [Scopi applicationis]

    Solet metiri effusio liquidi in continenti piscina temperatura ad quandam altitudinem ob fibrarum capillarium effectum, ut aquae effusio et aeris permeabilitatem fabricarum aestimaret.

                     

    [Relata signa]

    FZ/T01071

    Technical parametri

    1. Maximum numerum radices test: 6 (250×30) mm

    2. Tensio clip pondus: 3± 0.5g

    3.Operating time range: ≤99.99min

    4. lacus magnitudine:(360×90×70) mm (capacitas liquida test circiter 2000mL)

    5. Scale:(-20 ~ 230)mm±1mm

    6.Working power supply: AC220V±10% 50Hz 20W

    7.Overall magnitudine:(680×182×470)mm

    8.Weight: 10kg

  • YY822B aqua Evaporatio Rate Detector (automatic saturitatem)

    YY822B aqua Evaporatio Rate Detector (automatic saturitatem)

    Usus est ad hygroscopiitatem perpendendam et ad textilia viva siccanda. GB/T 21655.1-2008 1. Color tactus screen initus et output, Sinica et Anglica operandi menu 2. Ponens range: 0 ~ 250g, praecisio 0.001g 3. Numerus stationum: 10 4Aadding methodus: latae sententiae 5. Sample size: 100mm× 100mm 6. Test pondus intervallum temporis occasus range 1~10) min 7. Modi terminationis testium duo sunt libitum: Missa mutationis (range 0.5~ 100%) Test tempus (2~ 99999) min, accuratio: 0.1s 8. test leo modum (tempus: minu...
  • YY822A aqua Evaporatio Rate Detector

    YY822A aqua Evaporatio Rate Detector

    Aestimatio hygroscopitatis et textorum vivorum exsiccatio. GB/T 21655.1-2008 8.3. 1. Color tactus screen initus et output, Sinica et Anglica operandi menu 2. Ponens range: 0~250g, praecisio 0.001g 3. Numerus stationum: X 4. Modus addit: manuale 5.Sample size: 100mm×100mm 6.Test pondus temporis intervallum occasum 1~10) min 7. Modi finiendi duo experimenti libitum sunt: ​​Missae rate mutationis (range 0.5~ 100%) Test tempus (2~ 99999) min, accuratio: 0.1s 8. Modus sincere tentationis ( tempus: minuta: ...
  • YY821A Fabricae Liquid Water Dynamic Transfer Tester

    YY821A Fabricae Liquid Water Dynamic Transfer Tester

    Solet examinare, aestimare et gradare liquorem aquae vivacem transferendi proprietatem fabricae. Cognitio unicae aquae resistentiae, aquae repellentia et aquae effusio structurae fabricae nititur structura geometrica, structura interna ac nucleo effusio notarum fibri fabricae et fimbriae. AATCC195-2011、SN1689、GBT 21655.2-2009. 1. Instrumentum ad imperium motoris notae, accuratae et stabili dicione instructum instructum est. 2.Advanced droplet injectio...
  • YY814A Fabrica Rainproof Tester

    YY814A Fabrica Rainproof Tester

    Potest probare aquam repellentem proprietatem fabricae vel materiae compositae sub diversis pressionis pluviae aquae. AATCC 35、(GB/T23321,ISO 22958 potest customised) 1. Color tactus screen ostentus, Sinica et Anglica operandi genus interface menu. 2. Core imperium components sunt 32-bit multifunctionales motherboards ex Italia et Gallia. 3.Precise imperium pressurae impellendi, tempus breve responsum. 4. Uti computatrale imperium, 16 frenum A/D acquisitio data, magna cura pressionis sensoris. 1. Impetus .. .
  • YY813B Fabricae Aquae Repellency Tester

    YY813B Fabricae Aquae Repellency Tester

    Usus ad probandum permeability resistentiam vestimentorum fabricae. AATCC42-2000 1. Standard absorbent paper size: 152×230mm 2. Standard absorbent paper pondus: accurate ad 0.1g 3. A sample clip longitudo: 150mm 4. B sample clip longitudo: 150±1mm 5. B fibulae specimen et pondus; 0.4536kg 6. Calix mensurans range: 500ml 7. Scinditur Sample: lamina ferrea materia, magnitudo 178×305mm. 8. Sample coniciendum installation angulus: 45 gradus. 9.Funnel: 152mm infundibulum vitreum, 102mm altum. 10. Imbre caput: materia aenea, diam exterior.
  • YY813A Fabricae Humorem Tester

    YY813A Fabricae Humorem Tester

    Usus est ad probandum humorem permeabilitatem variarum larvarum. GB/T 19083-2010 GB/T 4745-2012 ISO 4920-2012 AATCC 22-2017 1.Glass infundibulum: Ф150mm×150mm 2. capacitas infundibuliformis: 150ml 3. Angulus specimen collocationis: et horizontalis in 45° 4. Spatium a COLLUM ad centrum exempli: 150mm 5. Sample frame diametri : Ф150mm 6. Magnitudo lance aquae (L×W×H) : 500mm×400mm×30mm 7. Compositus mensurae poculi: 500ml 8. Figura instrumenti (L×W×H) : 300mm×360mm×550mm 9. Instrumentum ponderis: circiter 5 kg...
  • YY812F Computerised aqua Permeability Tester

    YY812F Computerised aqua Permeability Tester

    Usus ad probandum aquae paginam resistentiam strictarum textiliarum, ut carbasa, oleum, pannum tentorium, pannus rayon, non texti, pluviae vestis, textilia obductis et fibrae incoctae. Resistentia aquae per fabricam exprimitur pressionis sub fabrica (aequivalens pressioni hydrostaticae). Accipe methodum dynamicam, methodum static et methodum programma celeriter, accurate, automatice experimentum methodi. GB/T 4744、ISO811、ISO 1420A、ISO 8096、 FZ/T 01004、AATCC 127、DIN 53886、BS 2823、JI...
  • YY812E Fabricae Permeability Tester

    YY812E Fabricae Permeability Tester

    Usus ad probandum aquae paginam resistentiam strictarum textiliarum, ut canvas, oilcloth, rayon, pannum tentorium et pannus germinis vestis. AATCC127-2003、GB/T4744-1997、ISO 811-1981、JIS L1092-1998、DIN EN 20811-1992( Loco DIN53886-1977)、FZ/T 01004. 1. Fixtura facta est ex ferro immaculato. 2. Pressura pretii mensurae utens summus praecisionem pressionem sensorem. 3. 7 pollicis color tactus velum, interface Sinica et Anglica. Menu modus operandi. 4. Core imperium components sunt 32-bit mu...
  • YY812D Fabricae Permeability Tester

    YY812D Fabricae Permeability Tester

    Usus est ad probandum aquae paginam resistentiam medicinae vestis tutelae, fabricae strictae, ut carbasus, oleum, tarpaulin, pannus tentorium et pannus germinis vestis. GB 19082-2009 GB/T 4744-1997 GB/T 4744-2013 AATCC127-2014 1. Ostentare et moderari: color tactus screen ostentus et operandi, operatio clavis metallica parallela. 2. Clamping modus: manuale 3. Dimensio mensurae: 0 ~ 300kPa (30MH2O); 0~100kPa (10mH2O); 0~50kPa (5MH2O) libitum est. 4. Consilium: 0.01kPa (1mmH2O) 5. accurationem mensurans: ≤±...